eco2lot smartcalc · Single volumes become the total volume

Volume counter

Scale, cycle, batch, pulse: many sources report every volume individually. The volume counter adds them to the volume per shift, day or month — the basis for every KPI per unit or tonne.

  • Units per cycle, litres per batch, kg per weighing, pulses
  • Volume per 15 minutes, hour, shift, day, week, month, year
  • Basis for KPIs per unit or tonne
my.eco2lot.de · Volume counter Source data point
What is a volume counter?

In eco2lot, a volume counter sums individually recorded volume values to a total volume per evaluation period. A filling line reports 120, 95 and 140 litres per batch — the volume counter delivers 355 litres for this shift. Unlike the feed counter, which forms the difference of a continuous meter reading, the volume counter adds every reported value: units per cycle, kilograms per weighing, litres per batch, pulses of a meter, generated energy per interval. The result is the volume per 15 minutes, hour, shift, day, week, month or year.

How it works

The calculation scheme

Calculation scheme volume counter Three individually reported batch volumes of 120, 95 and 140 litres are added. Result: 355 litres in this shift. 120 l Batch 1 + 95 l Batch 2 + 140 l Batch 3 · … = 355 l Volume of this shift (sum)
Three batches with 120, 95 and 140 litres: the volume counter adds the single values to 355 litres for this shift — and likewise for every hour, every day, month or year. The feed counter, in contrast, forms the difference of a meter reading.
What it looks like

From the single volumes to the sum per period

The evaluation of a volume counter looks like that of a feed counter: bars per period, table with sum, minimum, maximum and average — here using an energy counter as the example.

Current week
Volume per day

Monday to Sunday as bars: the weekly profile shows production days and weekend at a glance, the table the weekly sum.

Current month
Volume per day in the month

The whole month day by day — with sum, minimum, maximum and average in the table below.

In detail

What is inside the volume counter

What the volume counter is

  • The sum of individually recorded volume values per period
  • Typical: units per cycle, kilograms per weighing, litres per batch, pulses
  • Likewise: generation or flow values per interval, such as PV generation
  • Counterpart of the feed counter, which forms the difference of a meter reading

Your benefitWhere there is no continuous meter reading, the volume counter turns single values into the total volume.

Which data it uses

  • One data point that reports every volume individually (cycle, batch, weighing, pulse, interval)
  • Timestamps from the history of the data point
  • Base unit and display unit, e.g. litres → m³

Your benefitThe meter at the machine or pipeline stays unchanged.

What eco2lot calculates

  • The sum of all single values per evaluation period
  • Production volumes for machines, batch volumes, generation volumes
  • Sum, minimum, maximum and average per evaluation
  • Comparison of periods and years

Your benefitProduction volume per shift and water consumption per day arise with the same logic.

What benefit arises

  • Volumes with no manual reading off and recalculating
  • Denominator for KPIs: kWh per unit, m³ per tonne
  • Input for sum counters across several machines
  • Assignment to order or batch with status to volume

Your benefitOnly with the volume does a consumption become assessable.

Your outcome

Afterwards you can …

  • You know the production volume per shift and the media consumption per day, with zero arithmetic.

  • Volumes are available as denominators for KPIs — kWh per unit, water per tonne.

  • Volumes of several machines can be bundled to the line or hall via sum counter.

Frequently asked questions

What you should know about the volume counter

What is a volume counter?

A calculation type that sums individually recorded volume values per period — units per cycle, kilograms per weighing, litres per batch, pulses of a meter. The result is the total volume per 15 minutes, hour, shift, day, week, month or year.

How does the volume counter differ from the feed counter?

The feed counter forms the difference of a continuously rising meter reading (10,250 minus 10,000 kWh). The volume counter sums individually reported volumes (120 + 95 + 140 litres). So the data source decides which calculation type fits: meter reading or single value. The evaluation — bars per period, table with sum — looks the same for both.

Can I record the production volumes of a line?

Yes. If the machine reports the piece count per cycle or batch, the volume counter sums it to the piece count per shift, day or month; if it delivers a continuous total counter, the feed counter is the right choice. Several machines are combined to the line by the sum counter.

How does the volume become a KPI?

With the calculation type KPI: a consumption (feed counter) divided by the volume (volume counter) per period — for example kWh per unit or m³ of water per tonne.

Can I place an alarm on the volume?

Yes. An alarm reports when the volume per shift stays below target, a batch exceeds the maximum volume or zero volume is counted for a whole hour — directly on the calculated volume data point.

Is the volume counter the right fit for your task?

Describe your starting point and your goal — we get back to you with a concrete recommendation of matching features and solutions, plus a price indication.

Configure your solution
Esc or click outside to close