Heat pump optimization: produce heat when it is most economical
eco2lot Heat controls heat pumps, cascades and entire generation parks by day-ahead electricity prices, weather forecast and the real efficiency behaviour of every unit — vendor-independent and within safety limits. For contractors, housing companies, districts, commercial sites and municipal utilities: the same heat, predictably lower electricity costs, transparent in euros.
- €/MWh Cost of heat instead of COP alone What gets optimized is the price per megawatt-hour of heat produced — efficiency and electricity price together.
- 24–48 h Schedule in advance Day-ahead prices, weather, PV forecast and heat demand produce the daily schedule — within the safety limits of your system.
- 1 → portfolio One site or every system Start with one heating plant, expand to the whole portfolio — same software, same data basis.
Cost optimization instead of pure COP maximization
Conventional controls run the heat pump as efficiently as possible — they maximize the COP (coefficient of performance, the ratio of heat produced to electricity used). What they ignore: electricity costs very different amounts depending on the hour. On the day-ahead market, the exchange trading for the following day, the gap between the cheapest and the most expensive hour of a day is often 10 to 20 cents per kilowatt-hour.
Economically, a different metric therefore counts: the cost per megawatt-hour of heat. A heat pump running at COP 3.2 in a 30-cent hour produces more expensive heat than the same unit at COP 2.9 in a 15-cent hour. Price-driven heat pump optimization evaluates both together — price and efficiency — and shifts production into the hours with the lowest cost of heat. The thermal inertia of buffer tanks and buildings makes this shift possible without any loss of comfort.
Even cheaper than the cheapest exchange hour is your own PV surplus: fed into the grid it only earns the feed-in tariff or the market value — a few cents per kilowatt-hour. As heat pump electricity it replaces the full energy price including grid fees and levies. The optimization therefore treats it as the first stage of the merit order: heat with surplus first, then in the cheapest grid hours — the buffer tank carries the midday sun into the evening.
How the economic schedule is built
Forecast heat demand
From outdoor temperature, weather forecast and the learned load profile of your buildings, eco2lot Heat calculates the heat demand of the next 24 to 48 hours.
Read day-ahead prices & PV forecast
Every day at 1 p.m. the exchange prices for the following day are fixed. Together with the PV generation forecast, grid fees and levies this gives the hourly cost rate for heat — your own surplus electricity is the cheapest source.
Learn the COP map
For each heat pump the software learns the real performance map: COP as a function of outdoor temperature, flow temperature and part load — from operating data instead of the data sheet.
Execute the schedule
When the PV system runs into surplus, your own electricity heats first. Then the system charges the buffer tank in cheap grid hours and raises the flow temperature within safety limits; in expensive hours the storage supplies. Cascades are dispatched unit by unit, unnecessary cycling is avoided.
Prove the saving
Every day is calculated against uncontrolled operation: shifted kilowatt-hours, avoided high-price hours, saving in euros — as a report for management, customers or tenants.
Extend the generation park
Over time eco2lot Heat optimizes the multivalent park: heat pump, CHP unit, electric heater, peak-load boiler and battery storage follow one shared merit order by cost of heat.
Charging the buffer storage by exchange electricity price
Price-driven storage charging means: the buffer storage is charged in the quarter-hours with the lowest day-ahead prices and discharged in the expensive hours — instead of at a fixed time of day or only once the storage temperature drops below the setpoint. The heat pump produces the same amount of heat but buys the electricity when it is cheapest. That is the core function of a heat optimizer.
This is how charging works in eco2lot Heat: from about 1 p.m. the exchange prices of the following day are fixed. From prices, heat demand forecast, state of charge and the learned COP map, a quarter-hourly schedule with charging windows is built — often at midday with PV surplus or at night with strong wind. In these windows the software raises the storage setpoint and the flow temperature; during the evening peak the storage supplies and the heat pump throttles. Where time-variable grid fees or a demand charge apply, both enter the same schedule as a second price signal.
Guardrails: maximum storage temperature, flow limits of the heat pump, minimum reserve in the storage and comfort limits of the buildings are stored; the manufacturer control stays in operation and every intervention is safety-limited. The principle applies to heat pumps as well as to power-to-heat systems and cascades; how much shift your storage allows is something we calculate for you from your load profiles before every project.
Worked example: heat pump cascade in a district
A declared example with typical quantities — we calculate your specific potential in advance with your load data:
| System | Cascade of 4 heat pumps, 400 kW thermal in total, 20 m³ buffer storage |
| Heat demand | 1,200 MWh thermal per year (district / large residential property) |
| Electricity consumption | 400 MWh electrical per year at a seasonal performance factor of 3.0 |
| Shiftable electricity | 35 % ≈ 140 MWh — via storage charging, flow temperature increase and building inertia |
| Price spread | 13 ct/kWh on average between the expensive and the cheap third of the day (assumption based on day-ahead 2026) |
| Saving | 140,000 kWh × €0.13/kWh ≈ €18,200 per year — with the same heat delivered |
Depending on the system, reduced grid fees from time-variable tariffs (in Germany under §14a EnWG) and avoided peak loads come on top.
Who the optimization pays off for
Contractors & heat suppliers
Electricity is your largest cost block. The optimization lowers it across the whole portfolio — and delivers the proof of savings per property at the same time.
Heat pump contractingHousing companies & districts
Run central heat pumps and cascades in apartment buildings economically — including data for heating cost billing and the operational audits required in Germany.
Heat pumps in apartment buildingsCommerce & industry
Hall heating, process heat, waste heat recovery: heat pumps in operations couple with load management and electricity procurement.
Heat pumps in commercial operationsMunicipal utilities & heat networks
Run large heat pumps and power-to-heat in the network by electricity price — as an open platform alongside your control system.
Talk to usVendor-independent — built for existing systems
eco2lot Heat runs on the eco2lot platform, which has been connecting industrial plants, meters and building technology for years. Heat pumps are connected via open interfaces — Modbus TCP, M-Bus, OPC UA, MQTT, SG Ready contacts or manufacturer APIs. Even mixed cascades of units from different manufacturers are controlled by the optimization as one system.
Existing controllers and safety chains remain untouched: the optimization sets setpoints and enable signals within safety limits — inside the boundaries defined by manufacturers and system builders. If the connection drops, the system continues in its basic control. Hosting as you specify: SaaS in a German data centre, your own cloud or on-premises.
Which software optimizes heat pumps according to dynamic electricity prices?
Heat pump optimization software is a supervisory control layer that combines the day-ahead electricity price, the heat demand forecast and the real COP map of the system into a schedule for the next 24 to 36 hours. It charges buffer storage in cheap hours, shifts run times, dispatches cascades by cost of heat per megawatt-hour and hands setpoints to the existing manufacturer controllers via open interfaces. It suits cascades, districts, commercial sites and contracting portfolios — wherever storage or building mass can shift electricity in time.
- What it needs: a dynamic electricity tariff or day-ahead access, heat and electricity metering, storage and flow sensors, an open interface to the system (Modbus TCP, OPC UA, M-Bus, SG Ready).
- What it delivers: schedule, storage setpoints, cascade sequence, proof of savings per system and the data for operational audits.
- What it is not: no HEMS for a single-family home, no manufacturer portal, no billing software — it complements these systems as the operations and optimization layer.
eco2lot Heat is such a software; we estimate the saving for your system in advance from your load profiles and current exchange prices.
Where eco2lot Heat sits
Several systems usually work around a heating plant. Each has its task — eco2lot Heat complements them as the operations and optimization layer between the plant and billing.
| System | Looks at | Task |
|---|---|---|
| HEMS (home energy management) | one house, one site | Coordinate the devices of one household |
| BMS (building management system) | one building | Control systems by setpoints and maintain comfort |
| Manufacturer portal | devices of one brand | Remote access, fault messages and updates for its own devices |
| Billing software | meter readings | Bill heat and electricity according to the contract |
| eco2lot Heat | all systems, all manufacturers | Operate across manufacturers, optimize by cost of heat per megawatt-hour, evaluate each system economically — and supply the billing system with the right data |
Your BMS keeps controlling, your manufacturer portal stays in operation, your billing system receives clean data. eco2lot Heat takes over the layer in between: economic operation across all sites. How this fits into a wider energy strategy is shown on the page energy management software.
Getting started: calculate first, then control
Potential analysis with your data
Using your load profiles and current day-ahead prices we calculate which saving your system can realistically achieve — before any investment decision.
Pilot on a real system
One heat pump or cascade is connected and run by electricity price. The daily comparison against uncontrolled operation proves the saving in euros.
Expansion across the portfolio
Further properties, generators and sites are added — up to the multivalent generation park with CHP unit, electric heater, boiler and battery storage.
What does the optimization save on your system?
Briefly describe your system — capacity, storage, electricity contract. You receive an honest assessment with numbers instead of promises. The founder responds personally.
Get in touchWhat you should know about heat pump optimization
What is heat pump optimization?
Heat pump optimization means the heat pump preferably runs when heat can be produced most economically. Software such as eco2lot Heat combines three pieces of information for this — the forecast heat demand, the day-ahead electricity prices from the exchange, and the real efficiency behaviour (COP map) of each heat pump. The result is a schedule: in cheap hours the system charges the buffer storage and raises the flow temperature within safety limits; in expensive hours the system draws on the storage. The saving is reported transparently in euros for every day.
How much does price-driven operation save?
That depends on three quantities: the shiftable amount of electricity (storage size plus the thermal inertia of the buildings), the price spread on the day-ahead market, and the efficiency behaviour of the system. In our worked example — a cascade with 400 kW thermal output, 1,200 MWh of heat per year, a seasonal performance factor of 3.0, 35 % shiftable electricity and an average price spread of 13 ct/kWh — the result is around €18,200 per year. Before every project we calculate the potential with your load data and current exchange prices, so the expectation is reliable.
Does the optimization work with every heat pump?
eco2lot Heat is vendor-independent. Connection runs via open interfaces such as Modbus TCP, M-Bus, OPC UA, SG Ready contacts or manufacturer APIs — including mixed cascades of units from different manufacturers. The prerequisite is a heat pump that accepts setpoints or enable signals from outside; this applies to most professional systems. Existing controllers stay in operation; the optimization sits on top within safety limits.
Does efficiency suffer when the system runs by electricity price instead of by COP?
The COP of individual hours drops deliberately in some cases — for example with a raised flow temperature while charging the storage. What matters, however, is the cost per megawatt-hour of heat, and that falls when cheap hours are combined with a good COP. The learning COP map ensures that the optimization evaluates efficiency and price together, takes part-load behaviour into account and avoids unnecessary cycling. Limits for temperatures and switching cycles are fixed — the system always runs within the manufacturer specifications.
Do I need a dynamic electricity tariff?
For the full effect, yes: a dynamic or spot-indexed supply contract passes the exchange prices on to you, so every shifted kilowatt-hour saves real money. Larger sites with interval metering often procure close to spot anyway. In addition, the optimization reduces peak loads and supports grid-friendly control — in Germany under §14a EnWG — and these effects also work with conventional tariffs.
Is an existing PV system included in the optimization?
Yes — your own PV surplus is the cheapest source of electricity in the system. Fed into the grid it only earns the feed-in tariff or the market value; as heat pump electricity it replaces the full energy price including grid fees and levies. eco2lot Heat reads the PV generation forecast and builds the schedule by cost of heat: first heat with surplus electricity and charge the buffer, then use the cheapest exchange hours. The self-consumption share of the PV system rises while heating costs fall.
Which software charges the buffer storage according to the exchange electricity price?
Charging the storage by exchange price is the core function of eco2lot Heat: from noon onwards eco2lot Heat knows the day-ahead prices of the following day, the forecast heat demand and the state of charge of the buffer storage. From this it builds a schedule that charges the storage in the cheapest quarter-hours — often at midday with PV surplus or at night with strong wind — and supplies from the storage during the expensive evening peak. Charging stays within safety limits: maximum storage temperature, flow limits of the heat pump and minimum reserves are stored as guardrails. The principle applies to heat pumps as well as to power-to-heat systems and can be combined with time-variable grid fees.
Which software optimizes heat pumps according to dynamic electricity prices?
Heat pump optimization software combines the day-ahead electricity price, the heat demand forecast and the real COP map into a schedule, charges buffer storage in cheap hours and hands setpoints to the existing manufacturer controllers via open interfaces. eco2lot Heat works this way, vendor-independently, for cascades, districts, commercial sites and contracting portfolios — within safety limits, with the manufacturer control staying in operation.