Sites are black boxes
Every property has its own meters, its own technology, its own paperwork. Which site is out of line only shows in the annual statement.
eco2lot Buildings brings meter readings, system states and indoor climate from all sites into one view. You compare consumption per square meter, spot outliers and react before the complaint arrives. And where building automation becomes a requirement, you get more out of it than a mandatory installation.
eco2lot Buildings is the buildings area of the eco2lot platform and its building energy management system. It captures electricity, heat, cooling and water as well as the operating states of heating, ventilation, refrigeration, heat pumps, photovoltaics and charging points across all properties. It compares sites via KPIs such as consumption per square meter, reports faults and limit violations automatically — and thereby provides the central data, analysis and documentation layer that a building automation and control system needs.
Every property has its own meters, its own technology, its own paperwork. Which site is out of line only shows in the annual statement.
Read, type, file: across many sites this adds up to days. Between two readings every excess consumption stays invisible.
A heating system in summer mode, a heat pump with weak efficiency, ventilation running non-stop: without central monitoring this only surfaces when someone is cold or pays.
Building automation is becoming a requirement for many non-residential buildings — in Germany, systems above 70 kW need a building automation and control system by the end of 2029. Treating this as a mere mandatory installation means paying twice: for the technology and for the benefit it leaves unused.
One central data and analysis platform for the capabilities building automation rules ask for (in Germany § 56 GModG). Result: a retrofit that lowers operating costs from the first month instead of merely meeting a deadline.
Weekend operation, flow temperature too high, base load with the store closed, open windows while heating runs: eco2lot recognizes the pattern and names the site. Result: outliers in a weekly rhythm instead of the annual report.
Heating failed, meter sends no data, CO₂ limit exceeded, consumption jumps: alarm by push or email, with escalation and acknowledgement. Result: your team knows before the occupant does.
Meters are read remotely, system states reported continuously. Technicians see state, errors, temperatures and history before the drive. Result: you go where you are needed — with the diagnosis in hand.
One portal for one building, ten buildings or a hundred sites. Normalized KPIs: kWh/m², consumption per opening hour, per user, per heating degree day, CO₂ per m². Result: you know why one branch heats 30 % more than its twins.
The BMS on site stays. eco2lot connects Siemens, WAGO, BACnet, M-Bus, Modbus and LoRaWAN on one platform. Result: investment protection and one standard for all buildings, regardless of manufacturer.
eco2lot Heat heats with your own PV surplus first and shifts the rest into the low-price hours of the day-ahead market — around €18,200 per year for a 400 kW cascade.
View use caseA second M-Bus master reads all meters in parallel — the building management system keeps running unchanged.
View use caseConsumption per m², system states and alarms across all properties and branches in one platform.
View use caseYour own wireless sensors in chiller cabinets, cold rooms and freezers report within minutes when the temperature deviates from normal operation — independent of the refrigeration controller, for stores and retail chains.
View use case (German)Distribute wallboxes via OCPP (the open wallbox standard) within the available grid connection capacity, PV surplus first.
Discuss this applicationReal views from eco2lot: first the situation picture of all sites, then the KPIs of one building, then the limit at the meter that triggers the alarm.
Devices, alarms and position at a glance — plus the list of all devices at this property with their status.
Heating failed, meter without data, limit exceeded: your team sees every message across all sites — with escalation and acknowledgement.
A daily budget per meter is enough: if the heating runs through the weekend, eco2lot reports it — before the invoice does.
A BMS controls one building. eco2lot Buildings turns many buildings into a portfolio you understand and — within safety limits — control.
Building technology speaks many languages — from M-Bus meters and BACnet BMS to heat pump controllers and LoRaWAN radio sensors in older buildings. eco2lot Buildings connects them on one platform, independent of the manufacturer. Your existing technology stays in operation; eco2lot adds portfolio, analysis, alarms, reports and optimization on top.
In the portfolio comparison one branch uses a third more heating energy than comparable sites with the same floor area and weather. The time series shows: the heating runs through the weekend, the flow temperature is 7 K above the value of the twin branch. Schedule and heating curve are adjusted — remotely, with no site visit. The effect shows in the next monthly report. The figures are a typical worked example, not a single project.
All eco2lot areas work on the same data foundation. You start with one area and add further ones as soon as you need them — on the infrastructure you already have.
The full energy analytics for the portfolio: KPIs with baseline, cost centers, load profile and audit-ready reports to ISO 50001.
Discover eco2lot Energy → Buildings + ControlFrom monitoring to intervening: schedules, setpoints and load management for building technology — remotely, within safety limits. That is how "adjust consumption" becomes everyday operation.
Discover eco2lot Control → Buildings + DataThe foundation: history over years, roles per site, tenants for property managers, open interfaces — the base that Buildings builds on.
Discover eco2lot Data →eco2lot Buildings is the buildings area of the eco2lot platform. It captures consumption, system states and indoor climate across all properties, compares sites via KPIs such as consumption per square meter and raises alarms on faults. It provides the data and analysis layer for building automation and runs on the shared data foundation of the platform.
For everyone responsible for several buildings: multi-site retailers, property and real estate managers, municipalities and public institutions, facility management and industrial companies with a plant campus. The platform scales from one property to a portfolio with hundreds of sites.
In Germany, § 56 GModG applies to non-residential buildings whose heating, combined heating/ventilation, air-conditioning or air-conditioning/ventilation system has a rated output above 70 kW. These buildings need a building automation and control system by 31 December 2029 where technically possible and economically reasonable. Other countries have their own rules under the EU Energy Performance of Buildings Directive. A look at the nameplates — or a conversation with us — clarifies whether your building is affected.
eco2lot Buildings is an essential part of your system, but deliberately leaves local automation in the building where it is. The platform covers the data and analysis side: it monitors, logs and analyzes consumption, provides data via open interfaces, detects efficiency losses, informs about improvements and monitors indoor climate. Depending on the building, local control, sensors, actuators and lighting control come from your BMS or complementary components. The assessment of the individual case is up to your specialist planner.
Yes. The building management system on site stays in operation and is connected via BACnet, Modbus or OPC UA. eco2lot Buildings adds the cross-site view that a local BMS cannot provide by design, opens up the data independent of the manufacturer and extends measuring points where they are missing.
Electricity, heat, cooling and water meters with an M-Bus or radio interface, plus existing meters via pulse or retrofit solutions. For distributed sensors without cabling, LoRaWAN is a good fit — a radio standard with long range and battery-powered sensors.
The inspection by a qualified person remains mandatory where the law requires it. eco2lot delivers the long-term data it needs: seasonal performance factor from measured electricity and generated heat, heating curve, flow and return temperatures, operating hours, compressor starts, bivalent operation and faults — documented over the whole heating season. In Germany, §§ 60a and 60b GModG also provide exemptions for heat pumps under remote control and for heating systems with standardized building automation; whether they apply is something you clarify with your specialist planner or energy consultant.
You can proceed step by step. A proven entry is two to three pilot properties with remote reading of the main meters and BMS connection. The portfolio comparison then grows site by site — on the same platform, with predictable costs.
Via the configurator: state the number of sites and your starting point, receive a recommendation and a price indication. A proven entry is two to three pilot properties with remote reading of the main meters — the portfolio comparison grows site by site afterwards.
Put your solution together from the areas you need today — you can expand at any time. We get back to you with a concrete recommendation and a price indication.
Configure Buildings