Costs only show up on the invoice
Peak loads and excess consumption become visible in the quarterly bill — weeks after they occurred. Countermeasures then deal with the past instead of running the plant.
eco2lot Energy turns meter readings into decisions: load profiles, KPIs and costs per area — based on the metering you already have, audit-ready to ISO 50001.
eco2lot Energy is the energy area of the eco2lot platform and its energy data management software. It captures electricity, gas, heat, water, cooling and compressed air from existing meters and systems, calculates energy KPIs and costs per cost center, normalizes consumption and produces audit-ready reports to ISO 50001 — the international standard for energy management systems.
Peak loads and excess consumption become visible in the quarterly bill — weeks after they occurred. Countermeasures then deal with the past instead of running the plant.
Meter readings are walked, typed and merged into spreadsheets. Every report costs hours, and every version raises new questions about the data basis.
ISO 50001 and, in Germany, the Energy Efficiency Act (EnEfG) demand reliable KPIs and evidence. Without a continuous data basis, every audit turns into a special operation.
You see live which area, which line and which machine consumes how much — as load profile, KPI and in euros. One main meter becomes a picture of who causes what.
Lower base load, spot peak loads, find leaks: customers achieve up to 20 % energy savings — depending on plant and demand, with traceable proof of success.
Energy performance indicators (EnPI), baselines and reports are generated automatically from live data. The audit draws on the same data set as your day-to-day business.
Capture electricity, gas, compressed air, steam, cooling and water from any manufacturer — with licensing that stays independent of the number of sensors.
View use casePeak shaving (actively capping load peaks) with dynamic thresholds lowers the annual demand charge.
View use caseEnergy performance indicators and the logbook are created during normal operation — the audit becomes a formality.
View use caseSynchronize generation, consumption and storage automatically — the electricity stays in your own operation.
Discuss this application
Existing meters and metering equipment stay in service — eco2lot Energy reads them via open protocols. You add new measuring points where transparency is missing.
A printed circuit board manufacturer evaluates 123 water meters plus heat and cooling flows with eco2lot. The efficiency of the generators (COP) is calculated continuously and correlated with the outdoor temperature — the platform automatically cleans phantom values from faulty sensors.
“It was the most sensible decision we have made in this area in the past five years.” — Plant management
All eco2lot areas work on the same data foundation. You start with one area and add further ones as soon as you need them — on the infrastructure you already have.
Energy and production data on one data basis: 12,400 kWh and 84,000 parts become the KPI 0.148 kWh per unit.
Discover eco2lot Production → Energy + ControlAnalysis turns into action: avoid peak loads automatically, raise self-consumption, lower base load — controlled within safety limits.
Discover eco2lot Control → Energy + BuildingsThe same energy KPIs across your whole portfolio: compare sites, spot outliers, report centrally.
Discover eco2lot Buildings →eco2lot Energy is the energy area of the eco2lot platform. It captures all energy and media consumption from existing meters, calculates KPIs and costs, visualizes load profiles and produces audit-ready reports to ISO 50001. It runs on the shared data foundation of the platform and can be combined with Production, Buildings and Control.
Energy monitoring displays consumption. eco2lot Energy goes further: KPIs with baseline, cost center allocation, normalization, reports and the bridge to active control via eco2lot Control. The platform follows the principle of active energy management — see, understand and intervene instead of only observing.
Electricity, gas, heat, cooling, water and compressed air — plus any further measured variables such as temperatures or flow rates. Each medium is managed with unit, tariff and cost center and can be combined into virtual measuring points by formula.
Yes. The platform delivers complete energy data across all media, automatically calculated EnPIs with baseline, target tracking and audit-ready reports. This covers the normative requirements of ISO 50001:2018 from daily operation — in Germany also those of the Energy Efficiency Act (EnEfG).
Yes. eco2lot Energy reads existing meters and metering equipment via open protocols such as Modbus, M-Bus, MQTT and OPC UA — independent of the manufacturer. Manual meter readings and CSV imports are possible as well until all measuring points are automated.
Fastest via the configurator: you describe your starting point and scope, we get back to you with a concrete recommendation and a price indication. A typical start connects the main meters of one site and then grows measuring point by measuring point.
Put your solution together from the areas you need today — you can expand at any time. We get back to you with a concrete recommendation and a price indication.
Configure Energy